A load-sensing valve is a flow control valve that adjusts the pump displacement according to the load pressure to meet the requirements of the actuator. The pump’s flow rate is affected by an external throttle installed between the pump and the actuator, but remains unaffected by load pressure across the entire range below the set pressure. A constant-power valve maintains a constant hydraulic pump output power starting from the control initiation point within its set range; the working pressure and flow rate strictly follow a hyperbolic relationship, ensuring optimal and efficient matching with the prime mover’s power.
TECHNICAL FEATURES
01. Three valves integrated into a single valve body—compact size with comprehensive control options.
02. Excellent opening/closing characteristics ensure stable pump operating pressure and energy efficiency.
03. High-strength, high-elongation cast iron valve body rated for peak pressure of 45 MPa.
SPECIFICATIONS
| Power Pressure Setting Range |
Pressure Cut-off Setting Range
|
Load-sensitive pressure differential range
|
Standard Load-Sensitive Pressure Differential Setting |
| 5-32MPa | 5-35MPa | 1.4-2.5MPa | 1.8MPa |